Skip to Main Navigation

Spain

Madrid

image

Data Table with caption

Building Energy Code (BEC) currently in-force Technical Code Of Building (cte)
Date of BEC publication 2006
BEC Jurisdiction National
Climate zone classification Mixed, Dry
Income Group High income
Type of BEC Combination (Prescriptive/Performance-Based )
BEC Coverage Passive design; Space Heating; Space Cooling; Water Heating*; Lighting
* denotes coverage is through the European Ecodesign Directive

Indicator Mandatory Minimum Requirements
Maximum Solar Heat Gain Coefficient (SHGC) Yes
Roof U-value (W/m². K) 0.4
Floors U-value (W/m². K) 0.49
External walls U-value (W/m². K) 0.49
Doors U-value (W/m². K) 5.7
Air leakage prevention Yes
Enforcement Mechanisms Thermal Transmittance or Insulation Calculations for Building Envelope; Glazing Factors for Fenestration; Permanent Shading; Air Barrier, Air Leakage, or Air Infiltration