Building Energy Code (BEC) currently in-force | Building Decree 2012 |
Date of BEC publication | 2008 |
BEC Jurisdiction | National |
Climate zone classification | Mixed, Humid |
Income Group | High income |
Type of BEC | Combination (Prescriptive/Performance-Based ) |
BEC Coverage | Passive design; Space Heating; Space Cooling; Water Heating; Lighting* |
GENERAL INQUIRIES
Netherlands
Amsterdam
* denotes coverage is through the European Ecodesign Directive
Types of Standards
On selection, change the data
Passive design (Residential)
Indicator | Mandatory Minimum Requirements |
---|---|
Maximum Solar Heat Gain Coefficient (SHGC) | Yes |
Roof U-value (W/m². K) | 0.27 |
Floors U-value (W/m². K) | 0.27 |
External walls U-value (W/m². K) | 0.27 |
Doors U-value (W/m². K) | 3.4 |
Air leakage prevention | Yes |
Enforcement Mechanisms | Thermal Transmittance or Insulation Calculations for Building Envelope; Solar Heat Gains Calculations for Building Envelope; Glazing Factors for Fenestration; Permanent Shading; Air Barrier, Air Leakage, or Air Infiltration |