Czechia

Prague

image

Data Table with caption

Building Energy Code (BEC) currently in-force Energy Management Act (No. 406/2000 Coll.); Decree On The Energy Performance Of Buildings (No. 264/2020 Coll.)
Date of BEC publication 2001
BEC Jurisdiction National
Climate zone classification Cool, Humid
Income Group High income
Type of BEC Combination (Prescriptive/Performance-Based )
BEC Coverage Unified BEC
* denotes coverage is through the European Ecodesign Directive

Indicator Mandatory Minimum Requirements
Maximum Solar Heat Gain Coefficient (SHGC) Yes
Roof U-value (W/m². K) 0.3
Floors U-value (W/m². K) 0.6
External walls U-value (W/m². K) 0.6
Doors U-value (W/m². K) 3.5
Air leakage prevention Yes
Enforcement Mechanisms Thermal Transmittance or Insulation Calculations for Building Envelope, Solar Heat Gains Calculations for Building Envelope, Glazing Factors for Fenestration, Permanent Shading